FX1S |
|
|
The controllers of the FX1S series deliver outstanding functionality with up to 30 inputs and outputs in a very compact package. The FX1S is ideal for applications in difficult-to-access installations and systems where normal servicing is not possible. The integrated real-time clock and maintenance-free EEPROM with capacity for up to 2,000 program steps make the FX1S an autonomous and very service-friendly system. |
|
|
|
FX1S-10MR |
FX1S-14MR |
FX1S-20MR |
FX1S-30MR |
|
|
|
|
|
Power supply |
100-240V AC / 24V DC |
No. of inputs |
6 |
8 |
12 |
16 |
No. of outputs |
4 |
6 |
8 |
14 |
Digital outputs |
Relay / Transistor |
Program cycle period per logical instruction |
0.55 - 0.7 µs |
User memory |
2000 steps EEPROM (internal) |
Dimensions in mm (WxHxD) |
60x90x75 |
60x90x75 |
75x90x75 |
100x90x75 |
|
|
|
The FX1N combines the benefits of an inexpensive compact controller with the flexible expansion capabilities of a modular control system. It can be expanded for up to 128 inputs and outputs and with a comprehensive range of special function modules.The FX1N also features a powerful integrated positioning controller. |
|
|
|
FX1N-14 |
FX1N-24 |
FX1N-40 |
FX1N-60 |
|
|
|
|
|
Power supply |
100-240 V AC/ 12-24 V DC |
No. of inputs |
8 |
14 |
24 |
36 |
No. of outputs |
6 |
10 |
16 |
24 |
Digital outputs |
Relay / Transistor |
Program cycle period per logical instruction |
0.55 -1 µs |
User memory |
8.000 steps EEPROM (internal), EEPROM/ EPROM cassettes (optional) |
Dimensions in mm (WxHxD) |
90x90x75 |
90x90x75 |
175x90x75 |
185x90x75 |
|
|
FX2N |
|
|
The FX2N has set the standards in the industrial automation sector and is one of the biggest-selling controllers worldwide. It has many features normally found in larger controllers like floating-point math, the ability to process 32-bit data words and a wide range of fully-configurable communications options. |
|
|
|
FX2N-16 M |
FX2N-32 M |
FX2N-48 M |
FX2N-64 M |
FX2N-80 M |
FX2N-128 M |
|
|
|
|
|
|
|
Power supply |
100-240V AC, 24V DC |
Inputs |
8 |
16 |
24 |
32 |
40 |
64 |
Outputs |
8 |
16 |
24 |
32 |
40 |
64 |
Digital outputs |
Relay, Transistor |
Program cycle period per logical instruction |
0.08µs |
User memory |
8000 steps PLC-Program (RAM internal), optional 16 k RAM/EEPROM |
Dimensions in mm (WxHxD) |
150x90x87 |
150x140x95 |
182x90x87 |
220x90x87 |
285x90x87 |
350x90x87 |
|
|
Powered Extension Units (DI/DO) |
|
|
FX2N-32E |
FX2N-48ER-DS |
FX2N-48ET |
FX2N-48ER |
FX0N-40ER |
|
|
|
|
|
|
Applicable PLCs |
FX3U / FX3G / FX1N |
FX3U / FX1N |
FX3U / FX1N |
FX3U / FX3G / FX1N |
FX1N |
Integrated Inputs |
16 (24VDC) |
24 (120VDC) |
24 (24VDC) |
24 (24VDC) |
24 (24VDC) |
Integrated Outputs |
16 |
24 |
24 (24VDC) |
24 |
16 (24VDC) |
Output Type |
Relay |
Relay |
Sink Trans.,Source Trans. |
Relay,Sink Trans.,Source Trans. |
Relay,Source Transistor |
Dimensions
(W x H x D) mm |
150 x 90 x 87 |
182 x 90 x 87 |
|
|
Unpowered Extension Units (DI/DO) |
|
|
FX2N-8ER |
FX2N-8EX |
FX2N-8EY |
FX2N-16EX |
FX2N-16EY |
|
|
|
|
|
|
Applicable PLCs |
FX3U / FX3UC / FX3G / FX1N |
Integrated Inputs |
4 (24VDC) |
8 (24VDC) |
|
16 (24VDC) |
|
Integrated Outputs |
4 |
|
8 |
16 |
Output Type |
Relay |
Sink Trans.,Source Trans.,Relay |
|
Relay |
Dimensions
(W x H x D) mm |
43 x 90 x 87 |
40 x 90 x 87 |
|
|
Analog Input |
|
|
FX1N-2AD |
FX2N-2AD |
FX2N-4AD |
FX2N-8AD (*2) |
|
|
|
|
|
Applicable PLCs |
FX1S / FX1N |
FX3U / FX3UC / FX3G / FX1N |
FX3U / FX3UC / FX1N |
Integrated Inputs |
2 |
2 |
4 |
8 |
Dimensions
(W x H x D) mm |
43 x 38.5 x 22 |
43 x 90 x 87 |
55 x 90 x 87 |
75 x 90 x 75 |
|
|
Analog Output |
|
|
FX1N-1DA-BD |
FX2N-2DA |
FX2N-4DA |
|
|
|
|
Applicable PLCs |
FX1S / FX1N |
FX3U / FX3UC / FX3G / FX1N |
Integrated Outputs |
1 |
2 |
4 |
Dimensions
(W x H x D) mm |
43 x 38.5 x 22 |
43 x 90 x 87 |
55 x 90 x 87 |
|
|
Combination Analog Input / Output Modules |
|
|
FX0N-3A |
FX2N-5A |
|
|
|
Applicable PLCs |
FX3U / FX3UC / FX1N |
FX3U / FX3UC / FX3G / FX1N |
Integrated Inputs |
2 |
4 |
Integrated Outputs |
1 |
1 |
Dimensions
(W x H x D) (mm) |
43 x 90 x 87 |
55 x 90 x 87 |
|
|
|
|
Temperature Input Options |
|
|
FX2N-4AD-TC |
FX2N-4AD-PT |
|
|
|
Applicable PLCs |
FX3U / FX3UC / FX3G /FX1N |
Integrated Inputs |
4 (Pt100 sensors) |
2,4 points (Thermocouple
and Pt100 sensor) |
Dimensions
(W x H x D) mm |
55 x 90 x 87 |
|
|
Networking Modules |
|
|
Ethernet |
Profibus |
|
FX2NC-ENET-ADP |
FX0N-32NT-DP |
|
|
|
Applicable PLCs |
FX1N / FX1S |
FX1N |
Communication Speed |
100 Mbps / 10 Mbps |
Max. 12 Mbps |
Communication Cable |
Ethernet with RJ45 connector |
Profibus cable with Profibus-DP connector |
Dimensions
W x H x D (mm) |
19 x 90 x 78 |
43 x 90 x 87 |
|
|
|
|
|
AS-i Master Module |
CC-Link |
|
|
FX2N-32ASI-M |
FX2N-16CCL-M |
FX2N-32CCL |
|
|
|
|
Applicable PLCs |
FX3U/FX3UC/FX1N |
FX3U/FX3UC/FX3G/FX1N |
FX3U/FX3UC/FX1N |
I/O Points |
8 |
8 |
8 |
Dimensions
W x H x D (mm) |
55 x 90 x 87 |
85 x 90 x 87 |
43 x 90 x 87 |
|
|
FX Interfaces and Power Supplies |
|
|
Interface Boards and Modules |
|
FX1N-CNV-BD |
|
|
Applicable PLCs |
FX1S / FX1N |
Description |
Function expansion board |
Dimensions
W x H x D (mm) |
43 x 38 x 14 |
|
|